Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Audiol Neurootol ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38479363

RESUMO

BACKGROUND: Correct individual tonotopic frequency stimulation of the cochlea plays an important role in the further development of anatomy based cochlear implantation. In this context frequency specific fitting of the basal electrode contact with a normal insertion depth can be difficult since it is often placed in a frequency range higher than 10 kHz and current audio processors only stimulate for frequencies up to 8.5 kHz due to microphone characteristics. This results in a mismatch of the high frequencies. Therefore, this study represents a proof of concept for a tonotopic correct insertion and aims to develop an algorithm for a placement of the basal electrode below 8.5 kHz in an experimental setting. METHODS: Pre- and postoperative flat-panel volume CT scans with secondary reconstructions were performed in 10 human temporal bone specimens. The desired frequency location for the most basal electrode contact was set at 8.25 kHz. The distance from the round window to the position where the basal electrode contact was intended to be located was calculated preoperatively using 3D-curved multiplanar reconstruction and a newly developed mathematical approach. A specially designed cochlear implant electrode array with customized markers imprinted on the silicone of the electrode array was inserted in all specimens based on the individually calculated insertion depths. All postoperative measurements were additionally validated using an otological planning software. RESULTS: Positioning of the basal electrode contact was reached with only a small mean deviation of 37 ± 399 Hz and 0.06 ± 0.37 mm from the planned frequency of 8.25 kHz. The mean rotation angle up to the basal electrode contact was 51 ± 5 °. In addition, the inserted electrode array adequately covered the apical regions of the cochleae. CONCLUSION: Using this algorithm, it was possible to position the basal electrode array contact in an area of the cochlea that could be correctly stimulated by the existing speech processors in the context of tonotopic correct fitting.

2.
Int J Mol Sci ; 25(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38473870

RESUMO

Neural stem cells (NSCs) have been recently identified in the neonatal rat medial geniculate body (MGB). NSCs are characterized by three cardinal features: mitotic self-renewal, formation of progenitors, and differentiation into all neuroectodermal cell lineages. NSCs and the molecular factors affecting them are particularly interesting, as they present a potential target for treating neurologically based hearing disorders. It is unclear whether an NSC niche exists in the rat MGB up to the adult stage and which neurogenic factors are essential during maturation. The rat MGB was examined on postnatal days 8, 12, and 16, and at the adult stadium. The cardinal features of NSCs were detected in MGB cells of all age groups examined by neurosphere, passage, and differentiation assays. In addition, real-time quantitative polymerase chain reaction arrays were used to compare the mRNA levels of 84 genes relevant to NSCs and neurogenesis. In summary, cells of the MGB display the cardinal features of NSCs up to the adult stage with a decreasing NSC potential over time. Neurogenic factors with high importance for MGB neurogenesis were identified on the mRNA level. These findings should contribute to a better understanding of MGB neurogenesis and its regenerative capacity.


Assuntos
Corpos Geniculados , Células-Tronco Neurais , Ratos , Animais , Neurogênese , Diferenciação Celular , Tálamo , RNA Mensageiro , Biologia Molecular
3.
Otol Neurotol ; 45(3): e234-e240, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38238926

RESUMO

HYPOTHESIS: Measurements of the cochlear duct length (CDL) are dependent on the resolution of the imaging dataset. BACKGROUND: Previous research has shown highly precise cochlear measurements using 3D-curved multiplanar reconstruction (MPR) and flat-panel volume computed tomography (fpVCT). Thus far, however, there has been no systematic evaluation of the imaging dataset resolution required for optimal CDL measurement. Therefore, the aim of this study was to evaluate the dependence of CDL measurement on the resolution of the imaging dataset to establish a benchmark for future CDL measurements. METHODS: fpVCT scans of 10 human petrous bone specimens were performed. CDL was measured using 3D-curved MPR with secondary reconstruction of the fpVCT scans (fpVCT SECO ) and increasing resolution from 466 to 99 µm. In addition, intraobserver variability was evaluated. A best-fit function for calculation of the CDL was developed to provide a valid tool when there are no measurements done with high-resolution imaging datasets. RESULTS: Comparison of different imaging resolution settings showed significant differences for CDL measurement in most of the tested groups ( p < 0.05), except for the two groups with the highest resolution. Imaging datasets with a resolution lower than 200 µm showed lower intraobserver variability than the other resolution settings, although there were no clinically unacceptable errors with respect to the Bland-Altman plots. The developed best-fit function showed high accuracy for CDL calculation using resolution imaging datasets of 300 µm or lower. CONCLUSION: 3D-curved MPR in fpVCT with a resolution of the imaging dataset of 200 µm or higher revealed the most precise CDL measurement. There was no benefit of using a resolution higher than 200 µm with regard to the accuracy of the CDL measurement.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Tomografia Computadorizada por Raios X/métodos , Ducto Coclear/cirurgia , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Tomografia Computadorizada de Feixe Cônico , Osso Petroso/diagnóstico por imagem , Osso Petroso/cirurgia , Implante Coclear/métodos
4.
HNO ; 72(3): 166-172, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-38180480

RESUMO

BACKGROUND: German university otorhinolaryngology has a need for digital teaching content. Case-based e­learning represents a digital teaching methodology. The data on student use of case-based e­learning in university teaching of ENT medicine are limited. OBJECTIVE: The aim of this work was to determine the extent to which voluntary case-based e­learning is used by otolaryngology students and what influence the quality of the e­learning has on motivation to use e­learning and on the interest in otolaryngology. MATERIALS AND METHODS: Fifteen voluntary e­learning cases were created based on the content of the ENT lecture in the winter semester 2022/2023. Subsequently, a descriptive evaluation of the usage statistics of the cases of 157 students was conducted. Likewise, an evaluation of the quality of the e­learning as well as the motivation to complete it and the interest in otorhinolaryngology was carried out using a voluntary questionnaire. RESULTS: Voluntary case-based e­learning was used to varying degrees by 66% of the students. The quality of e­learning correlated significantly with the motivation and the interest in otolaryngology. CONCLUSION: The teaching content of otorhinolaryngology can be implemented sufficiently in case-based e­learning and is characterized by satisfactory student acceptance. Integration should be accomplished in a high-quality manner to increase motivation and interest in otorhinolaryngology.


Assuntos
Instrução por Computador , Estudantes de Medicina , Humanos , Aprendizagem , Currículo , Avaliação Educacional , Ensino
5.
Otol Neurotol ; 45(1): 11-17, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38085759

RESUMO

OBJECTIVE: To investigate the surgical approach and the audiological outcome of a stapes head coupler in active middle ear implant surgery. STUDY DESIGN: Retrospective data analysis. SETTING: Tertiary referral center with a large active middle ear implant program. PATIENTS: Twelve patients with active middle ear implant surgery. INTERVENTIONS: Therapeutic surgical approach for hearing rehabilitation in human subjects. MAIN OUTCOME MEASURES: Auditory brainstem response, sound field thresholds, vibrogram, speech perception in the Freiburger monosyllabic word test. RESULTS: The stapes head was attached safely in different coupling situations. Audiological outcomes were similar to the audiological performance of established vibroplasty couplers presented in the literature. CONCLUSION: The stapes head coupler is a new and safe tool for vibroplasty with a good audiological outcome.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Prótese Ossicular , Humanos , Estribo , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Estudos Retrospectivos , Audição , Resultado do Tratamento
6.
Acta Otolaryngol ; 143(11-12): 931-935, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38127466

RESUMO

Background: The cochlear aqueduct (CA), which connects the scala tympani and the subarachnoid space, and its accompanying structures appear to have a significant relevance during cochlear implantation and an accurate visualization in clinical imaging is of great interest. Aims and Objective: This study aims to determine which potential and limitations clinically available imaging modalities have in the visualization of the CA. Methods: Micro-CT, flat-panel volume computed tomography with and without secondary reconstruction (fpVCT, fpVCTseco) and multislice computed tomography (MSCT) of 10 temporal bone specimen were used for 3D analysis of the CA. Results: FpVCTseco proved superior in visualizing the associated structures and lateral portions of the CA, which merge into the basal turn of the cochlea. All clinical imaging modalities proved equal in analyzing the length, total volume of the CA and its area of the medial orifice. Conclusion: The choice of the most accurate clinical imaging modality to evaluate the CA and its associated structures depends on the clinical or scientific question. Furthermore, this study should provide a basis for further investigations analyzing the CA.


Assuntos
Implante Coclear , Implantes Cocleares , Aqueduto da Cóclea/diagnóstico por imagem , Aqueduto da Cóclea/cirurgia , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Implante Coclear/métodos , Osso Temporal/cirurgia , Microtomografia por Raio-X
7.
Life (Basel) ; 13(9)2023 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-37763262

RESUMO

Neural stem cells (NSCs) have previously been described up to the adult stage in the rat cochlear nucleus (CN). A decreasing neurogenic potential was observed with critical changes around hearing onset. A better understanding of molecular factors affecting NSCs and neurogenesis is of interest as they represent potential targets to treat the cause of neurologically based hearing disorders. The role of genes affecting NSC development and neurogenesis in CN over time on hearing capacity has remained unclear. This study investigated the mRNA abundance of genes influencing NSCs and neurogenesis in rats' CN over time. The CN of rats on postnatal days 6, 12, and 24 were examined. Real-time quantitative polymerase chain reaction arrays were used to compare mRNA levels of 84 genes relevant to NSCs and neurogenesis. Age- and hearing-specific patterns of changes in mRNA abundance of neurogenically relevant genes were detected in the rat CN. Additionally, crucial neurogenic factors with significant and relevant influence on neurogenesis were identified. The results of this work should contribute to a better understanding of the molecular mechanisms underlying the neurogenesis of the auditory pathway.

8.
Life (Basel) ; 13(5)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37240833

RESUMO

The medial geniculate body (MGB) is a nucleus of the diencephalon representing a relevant segment of the auditory pathway and is part of the metathalamus. It receives afferent information via the inferior brachium of the inferior colliculus and transmits efferent fibers via acoustic radiations to the auditory cortex. Neural stem cells (NSCs) have been detected in certain areas along the auditory pathway. They are of great importance as the induction of an adult stem cell niche might open a regenerative approach to a causal treatment of hearing disorders. Up to now, the existence of NSCs in the MGB has not been determined. Therefore, this study investigated whether the MGB has a neural stem cell potential. For this purpose, cells were extracted from the MGB of PND 8 Sprague-Dawley rats and cultured in a free-floating cell culture assay, which showed mitotic activity and positive staining for stem cell and progenitor markers. In differentiation assays, the markers ß-III-tubulin, GFAP, and MBP demonstrated the capacity of single cells to differentiate into neuronal and glial cells. In conclusion, cells from the MGB exhibited the cardinal features of NSCs: self-renewal, the formation of progenitor cells, and differentiation into all neuronal lineage cells. These findings may contribute to a better understanding of the development of the auditory pathway.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...